1-Undecanethiol

Synonyms & Trade Names
Undecyl mercaptan
CAS No.
5332-52-5
RTECS No.
DOT ID & Guide
1228 131
Formula
CH₃(CH₂)₁₀SH
Conversion
1 ppm = 7.71 mg/m3
IDLH
N.D.
See: IDLH INDEX
Exposure Limits
NIOSH REL
C 0.5 ppm (3.9 mg/m3) [15-minute]
OSHA PEL
none
Measurement Methods
None available
See: NMAM or OSHA Methods
Physical Description
Liquid.
Molecular Weight
188.4
Boiling Point
495°F
Freezing Point
27°F
Solubility
Insoluble
Vapor Pressure
?
Ionization Potential
?
Specific Gravity
0.84
Flash Point
?
Upper Explosive Limit
?
Lower Explosive Limit
?
Combustible Liquid
Incompatibilities & Reactivities
Oxidizers, reducing agents, strong acids & bases, alkali metals
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms
irritation eyes, skin, respiratory system; confusion, dizziness, headache, drowsiness, nausea, vomiting, lassitude (weakness, exhaustion), convulsions
Target Organs
Eyes, skin, respiratory system, central nervous system
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet (flammable)
Change:No recommendation
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH

Up to 5 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)
(APF = 10) Any supplied-air respirator

Up to 12.5 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)

Up to 25 ppm:
(APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 1621
Page last reviewed: October 30, 2019