Monomethyl aniline

Synonyms & Trade Names
MA, (Methylamino)benzene, N-Methyl aniline, Methylphenylamine, N-Phenylmethylamine
CAS No.
100-61-8
RTECS No.
DOT ID & Guide
2294 153
Formula
C₆H₅NHCH₃
Conversion
1 ppm = 4.38 mg/m3
IDLH
100 ppm
See: 100618
Exposure Limits
NIOSH REL
TWA 0.5 ppm (2 mg/m3) [skin]
OSHA PEL
TWA 2 ppm (9 mg/m3) [skin] See Appendix G
Measurement Methods
NIOSH 3511
See: NMAM or OSHA Methods
Physical Description
Yellow to light-brown liquid with a weak, ammonia-like odor.
Molecular Weight
107.2
Boiling Point
384°F
Freezing Point
-71°F
Solubility
Insoluble
Vapor Pressure
0.3 mmHg
Ionization Potential
7.32 eV
Specific Gravity
0.99
Flash Point
175°F
Upper Explosive Limit
?
Lower Explosive Limit
?
Class IIIA Combustible Liquid: Fl.P. at or above 140°F and below 200°F.
Incompatibilities & Reactivities
Strong acids, strong oxidizers
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms
lassitude (weakness, exhaustion), dizziness, headache; dyspnea (breathing difficulty), cyanosis; methemoglobinemia; pulmonary edema; liver, kidney damage
Target Organs
respiratory system, liver, kidneys, blood, central nervous system
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:No recommendation
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH

Up to 5 ppm:
(APF = 10) Any supplied-air respirator

Up to 12.5 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode

Up to 25 ppm:
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 100 ppm:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 0921   MEDICAL TESTS: 0151
Page last reviewed: October 30, 2019