Certification Sequence and Quality Requirements following the 42CFR Part 84 Requirements


Table 1. Submission Requirements (Systems)

Number of Available Sizes = 2

Sample Conditioning"As Received"
Quantities
Environmentally
Conditioned
Quantities
Grand
Total
Size DesignationS/MM/LTotalS/MM/LTotal
Blower On/Off CO2 Machine Test12Reuse*00Reuse*Reuse*
Blower On LRPL14152900029
Blower Off LRPL44Reuse*00Reuse*Reuse*
Application Reference0110001
Live Agent Testing0220446
Spare Queue0000444
Column Total14183208840

* Units used for CO2 machine test are taken from blower on LRPL pool and then reused as test has no effect on unit. Test do not affect system submission requirements.

 

Table 2. Submission Requirements (Canisters)

Sample Usage# of Canisters
Test Representative Agent (TRA) Challenge60
P100 Particulate Challenge (DOP)20
Live Agent Testing12
Spare Queue10
Total102

NOTE: All canisters environmentally conditioned.

 