Fatality Assessment and Control Evaluation (FACE) Program |
|
69-Year-Old Sanitation Worker Run Over by Refuse Truck |
|
|||||||||||
SummaryOn October 17, 2008, a 69-year-old male private sector sanitation worker died after he was run over by a refuse truck. On the day of the incident, the victim and one other worker were collecting tree brush in a rural southern New Jersey community. The workers had stopped the rear-loading compaction truck and began to load brush into the rear compartment. Soon after initiating the compaction cycle of the truck, the vehicle began to move, uncontrolled, in a forward direction. Both workers immediately ran after the vehicle, and the decedent fell under the truck and was crushed to death. NJ FACE investigators recommend that these safety guidelines be followed to prevent similar incidents:
IntroductionOn October 17, 2008, a Federal OSHA compliance officer notified NJ FACE staff of the death of a 69-year-old worker who was killed after being run over by a rear-loading compactor refuse truck. A NJ FACE investigator contacted the employer and arranged to conduct an investigation, which took place on October 22, 2008. During the visit, the NJ FACE investigator interviewed the immediate supervisor and colleagues of the decedent. Additional information was obtained from the medical examiner’s report, death certificate, and employer incident summary. The company that employed the decedent was a trash collection and trucking company that collected trash once per week, and tree brush once every two weeks. The victim had many years of experience in the waste collection industry; at the time of the incident he was retired and working part time. He was a member of the local union prior to retirement, and the other worker was a current member. Employee training, including health and safety training, was conducted on the job by the employer. Back to TopInvestigationThe incident occurred on a clear October day (approximately 65oF, no wind). A two-person crew was assigned to collect brush for a rural southern New Jersey township. The decedent was functioning as the driver, and the other worker (the “helper”) rode in the passenger seat until arrival at a pick-up point. The truck they were operating was a 300-horsepower, rear-loading, compactor refuse recycling truck. The route was a one-load route; that is, they only filled the truck once during the day; no mid-route dumping was conducted. The workers left the yard where the truck was stored at 6:00 am that morning. The workers arrived at the assigned route in approximately 45 minutes. A few streets into the collection, the truck pulled up to a stop near a curb to load brush into the compaction unit. The helper, who was usually on the truck, chose to walk behind the truck from the previous stop. The decedent stopped the truck facing the next stop, which was northbound on the left side of the road. (see Figures 1 and 2). He then exited the truck to assist with the load. While the two workers were loading the brush, the helper activated the “speed-up button,” which triggers the engine to run faster (at approximately 2,000 rpm) to power the hydraulic system of the load compactor, which crushes and compacts the load (see Figure 3). As soon as the button was pushed, the truck unexpectedly started moving forward, traveling northbound. Both workers ran to catch up to the truck; the decedent ran along the driver side between the truck and the curb, and the helper ran along the passenger side. The helper was able to catch up to the vehicle and hit the speed-up button which slowed the truck’s movement. The helper reached the passenger-side door and managed to enter the cab and fully stop the truck. He then exited the cab, looked around on the other side of the vehicle for the decedent, and saw that he had been crushed by the driver’s side wheels. The truck had moved approximately 50 feet north through an intersection with traffic lights. No one else was injured. Back to TopRecommendations/DiscussionRecommendation #1: Sanitation workers should be trained on the safe procedures for operating and loading sanitation trucks, including auxiliary compactor equipment.Discussion: Training is a critical aspect of the prevention of injuries in any potentially hazardous working condition. Many of these conditions are evident in the waste collection industry, including struck-by, crushing, and fall hazards. In NJ, since 1991, there have been 25 workers killed while working on or near sanitation trucks, and many nonfatal injuries. Training can help combat these risks, and there are already many educational materials that address this industry, including the following:
Recommendation #2: Sanitation truck drivers should not leave the vehicle unless needed as a spotter; in which case, the gear shift should be set to “neutral” and the emergency brakes engaged.Discussion: Recommendation # 3: Equipment should be in good working order, and safety interlocks or other control mechanisms should never be modified, disconnected, or disengaged.Discussion: The particular model of truck involved in this incident had the neutral relay removed and the “speed-up” button was converted to a toggle switch. A properly working neutral relay prevents the compactor cycle to be activated while the vehicle is in “drive.” The compactor cycle was therefore able to be engaged while the truck was moving from stop-to-stop. The speed-up button, which activates the compactor, was designed by the manufacturer to activate one full compaction cycle. In this incident, the modifications to the compactor enabled it to be started and stopped at any time. These two alterations compromised the safety of the equipment. As per ANSI Z245.1, Section 6.2.1 (j), “No one should disable or bypass safety equipment or other protective devices,” and “Mobile equipment must not be operated unless these devices are fully functional.” Recommendation #4: A safety and health plan based on a job hazard analysis should be developed by the employer and followed for each trash route.Discussion: Employers should conduct a job hazard analysis, with the participation of employees, of all work areas and job tasks. A job hazard analysis should begin by reviewing the work activities for which the employee is responsible, and the equipment that is needed. Each task is further examined for mechanical, electrical, chemical, or any other hazard the worker may encounter. A source of information on conducting a job hazard analysis is included in the Appendix.
Back to TopAppendixRecommended Resources
U.S. Department of Labor, Occupational Safety & Health Administration (OSHA)
Back to TopReference
New Jersey FACE ProgramFatality Assessment and Control Evaluation (FACE) ProjectInvestigation #08-NJ-079 Staff members of the New Jersey Department of Health and Senior Services, Occupational Health Service, perform FACE investigations when there is a report of a targeted work-related fatal injury. The goal of FACE is to prevent fatal work-related injuries by studying the work environment, the worker, the task, the tools the worker was using, the energy exchange resulting in the fatal injury, and the role of management in controlling how these factors interact. FACE gathers information from multiple sources that may include interviews of employers, workers, and other investigators; examination of the fatality site and related equipment; and reviewing OSHA, police, and medical examiner reports, employer safety procedures, and training plans. The FACE program does not determine fault or place blame on employers or individual workers. Findings are summarized in narrative investigation reports that include recommendations for preventing similar events. All names and other identifiers are removed from FACE reports and other data to protect the confidentiality of those who participate in the program. NIOSH-funded state-based FACE Programs include: California, Iowa, Kentucky, Massachusetts, Michigan, New Jersey, New York, Oregon, and Washington. Please visit the NJ FACE website at www.state.nj.us/health/eoh/survweb/face.htm or the CDC/NIOSH FACE website at www.cdc.gov/niosh/face for more information. The NJ FACE Project is supported by Cooperative Agreement #1 U60 OH0345-01 from the Centers for Disease Control and Prevention (CDC). The contents of this report are solely the responsibility of the authors and do not necessarily represent the official views of the CDC. To contact New Jersey State FACE program personnel regarding State-based FACE reports, please use information listed on the Contact Sheet on the NIOSH FACE web site. Please contact In-house FACE program personnel regarding In-house FACE reports and to gain assistance when State-FACE program personnel cannot be reached. |
||||||||||||