NIOSHTIC-2 Publications Search

Evaluation of N95 respirator use with a surgical mask cover: effects on breathing resistance and inhaled carbon dioxide.

Authors
Sinkule EJ; Powell JB; Goss FL
Source
Ann Occup Hyg 2013 Apr; 57(3):384-398
NIOSHTIC No.
20041734
Abstract
Objective: For pandemic influenza outbreaks, the Institute of Medicine has recommended using a surgical mask cover (SM) over N95 filtering facepiece respirators (FFRs) among healthcare workers as one strategy to avoid surface contamination of the FFR which would extend its efficacy and reduce the threat of exhausting FFR supplies. The objective of this investigation was to measure breathing air quality and breathing resistance when using FFRs with US Food and Drug Administration-cleared SM and without SM. Methods: Thirty National Institute for Occupational Safety and Health (NIOSH)-approved FFR models with and without SM were evaluated using the NIOSH Automated Breathing and Metabolic Simulator (ABMS) through six incremental work rates. Results: Generally, concentrations of average inhaled CO2 decreased and average inhaled O2 increased with increasing O2 consumption for FFR+SM and FFR-only. For most work rates, peak inhalation and exhalation pressures were statistically higher in FFR+SM as compared with FFR-only. The type of FFR and the presence of exhalation valves (EVs) had significant effects on average inhaled CO2, average inhaled O2, and breathing pressures. The evidence suggests that placement of an SM on one type of FFR improved inhaled breathing gas concentrations over the FFR without SM; the placement of an SM over an FFR+EV probably will prevent the EV from opening, regardless of activity intensity; and, at lower levels of energy expenditure, EVs in FFR do not open either with or without an SM. Conclusions: The differences in inhaled gas concentrations in FFR+SM and FFR-only were significant, especially at lower levels of energy expenditure. The orientation of the SM on the FFR may have a significant effect on the inhaled breathing quality and breathing resistance, although the measurable inhalation and exhalation pressures caused by SM over FFR for healthcare users probably will be imperceptible at lower activity levels.
Keywords
Personal-protective-equipment; Respirators; Respiratory-equipment; Face-masks; Breathing; Air-purifying-respirators; Airway-resistance; Dioxides; Infectious-diseases; Infection-control; Author Keywords: breathing resistance; effects from using N95 respirators; extending N95 respirators during influenza outbreak; inhaled carbon dioxide; inhaled oxygen; metabolic simulator; N95 respirator; respiratory protection; surgical mask; using N95 respirators with surgical or procedure masks
Contact
E.J. Sinkule, National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Pittsburgh, PA, USA
CODEN
AOHYA3
CAS No.
124-38-9
Publication Date
20130401
Document Type
Journal Article
Email Address
ESinkule@cdc.gov
Fiscal Year
2013
Identifying No.
B20121218B
Issue of Publication
3
ISSN
0003-4878
NIOSH Division
NPPTL
Priority Area
Healthcare and Social Assistance
Source Name
Annals of Occupational Hygiene
State
PA
Page last reviewed: May 11, 2023
Content source: National Institute for Occupational Safety and Health Education and Information Division