Several devices based on ECG can acquire beat-to-beat intervals, and some of these devices may be used for heart rate variability (HRV) analysis. Most of these devices and their methods to acquire the beat-to-beat intervals need to be validated for HRV analysis by comparing them against traditional methods. Some of these methods have low temporal resolution, which may be sufficient for certain studies. HRV analysis parameters obtained from two methods differing in temporal resolution were compared to the HRV analysis parameters obtained from a referent method (ECG). One of the methods had a high resolution (<1 ms) and the other method had a low resolution (10 ms). Seven healthy male volunteers participated in the study. The beat-to-beat intervals were collected simultaneously from the three methods and the HRV parameters derived from them were used for our comparisons. The Pearson product-moment correlations were used, which demonstrated an excellent correlation (r > 0.99) in time domain, frequency domain and some non-linear HRV measures. The HRV measures were further analyzed using the one-way repeated-measures analysis of variance (ANOVA) and statistically significant differences were observed in some of the HRV parameters obtained from the low-resolution method, especially the mean RR (p < 0.001) and the mean heart rate (p < 0.001). Since the same software was used for HRV analysis of the three methods, any differences were due to the temporal resolution of the RR intervals measured by the methods. Overall, both the methods correlated very well with the referent method among healthy volunteers in resting conditions and may be used by researchers for HRV studies.
Engineering and Control Technology Branch, National Institute for Occupational Safety and Health, 1095 Willowdale Road, M/S 2027, Morgantown, WV 26505, USA
Links with this icon indicate that you are leaving the CDC website.
The Centers for Disease Control and Prevention (CDC) cannot attest to the accuracy of a non-federal website.
Linking to a non-federal website does not constitute an endorsement by CDC or any of its employees of the sponsors or the information and products presented on the website.
You will be subject to the destination website's privacy policy when you follow the link.
CDC is not responsible for Section 508 compliance (accessibility) on other federal or private website.
For more information on CDC's web notification policies, see Website Disclaimers.
CDC.gov Privacy Settings
We take your privacy seriously. You can review and change the way we collect information below.
These cookies allow us to count visits and traffic sources so we can measure and improve the performance of our site. They help us to know which pages are the most and least popular and see how visitors move around the site. All information these cookies collect is aggregated and therefore anonymous. If you do not allow these cookies we will not know when you have visited our site, and will not be able to monitor its performance.
Cookies used to make website functionality more relevant to you. These cookies perform functions like remembering presentation options or choices and, in some cases, delivery of web content that based on self-identified area of interests.
Cookies used to track the effectiveness of CDC public health campaigns through clickthrough data.
Cookies used to enable you to share pages and content that you find interesting on CDC.gov through third party social networking and other websites. These cookies may also be used for advertising purposes by these third parties.
Thank you for taking the time to confirm your preferences. If you need to go back and make any changes, you can always do so by going to our Privacy Policy page.