Urinary biomarkers of 1-bromopropane exposure: evaluation of LC/MS analytical test procedures for quantification.
Authors
Cheever KL; Marlow KL
Source
Occupational and Environmental Exposures of Skin to Chemicals, Stockholm, Sweden, June 12 -15, 2005. Morgantown, WV: National Institute for Occupational Safety and Health, 2005 Jun; :1-2
Link
NIOSHTIC No.
20027237
Abstract
An LC/MS procedure was evaluated for the quantification of N-acetyl-S-(n-propyl)-L-cysteine (propylmercapturic acid, PMA) in urine. PMA is a metabolite and biomarker for exposure to 1-bromopropane (1-BP: n-propylbromide, CAS Registry no. 106-94-5), an industrial solvent that is being used as a replacement for potential ozone depleting chlorofluorocarbons. 1-BP is a health concern for exposed workers because of reported chronic toxicity. Central neurological and peripheral neuropathy disorders have been reported in workers exposed to 1-BP; reproductive and hematopoietic disorders have been reported in rats. 1-BP is readily absorbed through the skin and of concern for human dermal exposure. Potential biomarkers for the evaluation of 1-BP exposure have been tried with varying degrees of success including urinary bromine, GC/EC analysis of 1-BP, and GC/MS analysis of 3-bromopropionic acid. The major metabolites of 1-BP, however, have been shown to include several mercapturic acids, the products of several metabolic pathways. To evaluate the utility of these as biomarkers, solid phase extraction conditions were developed for sample preparation of urine for the analysis of PMA as well as PMA-S-oxide, N-acetyl-S-(3-hydroxypropyl)-L-cysteine and N-acetyl-S-(2-carboxyethyl)-L-cysteine. LC conditions for chromatographic separation were coupled with electrospray "soft ionization" and mass spectrometry. Positive ion ESI LC/MS/MS product scanning was performed for structural analysis. Initially, a Finnegan MAT LCQ ion trap tandem MS/MS was used to evaluate mercapturic acid formation, and the major 1-BP urinary product, PMA, appeared to be the most useful biomarker. Subsequently, PMA alone was routinely analyzed using an Agilent 1100 LC/MSD SL mass spectrometer system using selected ion monitoring (SIM) in the negative ion ESI LC/MS mode for maximum sensitivity. d7-PMA was used as internal standard and samples were extracted using Varian BondElute C18 solid phase extraction (SPE) columns. Sample extracts were injected onto a 150-mm X 2.0-mm (id) Aqua C-18 Phenomenex column and eluted using a water:methanol (0.1% acetic acid) gradient. Optimal instrument parameters for MS analysis of the mercapturic acid product was determined. Recovery studies using 10, 5, 1.25 and 0.61 µg/ml PMA fortified human urine samples demonstrated good accuracy and precision with recoveries using the SPE procedure of between 93-102% with precision measured as percent relative standard deviation (%RSD) as high as 5.2%. This biomarker was used for the evaluation of 1-BP exposure at numerous field sites. The solid phase extraction procedure was amenable to robotic automation which was less labor intensive and demonstrated better precision than manual sample preparation. PMA analysis appears to be a useful biomarker for the evaluation of 1-BP exposure.
Links with this icon indicate that you are leaving the CDC website.
The Centers for Disease Control and Prevention (CDC) cannot attest to the accuracy of a non-federal website.
Linking to a non-federal website does not constitute an endorsement by CDC or any of its employees of the sponsors or the information and products presented on the website.
You will be subject to the destination website's privacy policy when you follow the link.
CDC is not responsible for Section 508 compliance (accessibility) on other federal or private website.
For more information on CDC's web notification policies, see Website Disclaimers.
CDC.gov Privacy Settings
We take your privacy seriously. You can review and change the way we collect information below.
These cookies allow us to count visits and traffic sources so we can measure and improve the performance of our site. They help us to know which pages are the most and least popular and see how visitors move around the site. All information these cookies collect is aggregated and therefore anonymous. If you do not allow these cookies we will not know when you have visited our site, and will not be able to monitor its performance.
Cookies used to make website functionality more relevant to you. These cookies perform functions like remembering presentation options or choices and, in some cases, delivery of web content that based on self-identified area of interests.
Cookies used to track the effectiveness of CDC public health campaigns through clickthrough data.
Cookies used to enable you to share pages and content that you find interesting on CDC.gov through third party social networking and other websites. These cookies may also be used for advertising purposes by these third parties.
Thank you for taking the time to confirm your preferences. If you need to go back and make any changes, you can always do so by going to our Privacy Policy page.