Urinary (2-methoxyethoxy) acetic acid: an effective gas chromatographic test method for quantification.
Authors
B'Hymer C; Cheever KL; Butler MA
Source
Applying Biomarkers to Occupational Health Practice, Santa Fe, NM, March 24-25, 2003. Atlanta, GA: Centers for Disease Control, 2003 Mar; :2
Link
NIOSHTIC No.
20027209
Abstract
(2-Methoxyethoxy) acetic acid (MEAA) is a metabolite and biomarker for exposure to 2-(2-methoxyethoxy) ethanol (diethylene glycol monomethyl ether, DEGME, or DiEGME) and bis(2-methoxyethyl) ether (diglyme); both are glycol ethers and are of concern because of the general toxicity of these compounds. Glycol ethers have been frequently reported to damage the male reproductive system, hemaopietic system, and fetal/embryonic development. Occupational exposure by these widely used glycol ethers is likely, since they are readily absorbed through the skin. Specifically, 2-(2-methoxyethoxy) ethanol is used as an anti-icing additive to the military jet fuel JP-8, and bis(2-methoxyethoxy) ether is an aprotonic solvent with industrial uses and is a component of some hydraulic fluids including brake fluid. A simple and effective general test method for MEAA in urine samples was developed to monitor any exposed population. Urine specimens were first spiked with deuterated (2-butoxy) acetic acid, which was used as a procedural internal standard. The samples were extracted with ethyl acetate, concentrated, and treated by acid catalyzed esterification to produce the corresponding ethyl esters of MEAA and the internal standard. Subsequently, the ethyl ester derivatives were extracted using methylene chloride and concentrated to produce the final solution for gas chromatographic analysis. A mass selective detector (MSD) using a 50-m X 0.20-mm (id) HP-1 capillary column and a temperature program of 50 to 230 degrees-C was used for the gas chromatographic measurement. Ion m/z 59 was monitored for the ethyl ester of MEAA and ion m/z 66 was monitored for the internal standard. A recovery study using 2, 10 and 20 micrograms/mL MEAA spiked urine samples demonstrated good accuracy and precision; recovery varied between 95-103%. The limit of detection (LOD) was found to be approximately 0.1 micrograms/mL. (0.8 micromoles/L) for this analysis method.
Links with this icon indicate that you are leaving the CDC website.
The Centers for Disease Control and Prevention (CDC) cannot attest to the accuracy of a non-federal website.
Linking to a non-federal website does not constitute an endorsement by CDC or any of its employees of the sponsors or the information and products presented on the website.
You will be subject to the destination website's privacy policy when you follow the link.
CDC is not responsible for Section 508 compliance (accessibility) on other federal or private website.
For more information on CDC's web notification policies, see Website Disclaimers.
CDC.gov Privacy Settings
We take your privacy seriously. You can review and change the way we collect information below.
These cookies allow us to count visits and traffic sources so we can measure and improve the performance of our site. They help us to know which pages are the most and least popular and see how visitors move around the site. All information these cookies collect is aggregated and therefore anonymous. If you do not allow these cookies we will not know when you have visited our site, and will not be able to monitor its performance.
Cookies used to make website functionality more relevant to you. These cookies perform functions like remembering presentation options or choices and, in some cases, delivery of web content that based on self-identified area of interests.
Cookies used to track the effectiveness of CDC public health campaigns through clickthrough data.
Cookies used to enable you to share pages and content that you find interesting on CDC.gov through third party social networking and other websites. These cookies may also be used for advertising purposes by these third parties.
Thank you for taking the time to confirm your preferences. If you need to go back and make any changes, you can always do so by going to our Privacy Policy page.