NIOSHTIC-2 Publications Search

Design and Construction of a Radiation Probe.

Authors
Schwartz-CH; Orning-AA
Source
NTIS: PB 194 945 :20 pages
Link
NIOSHTIC No.
10009112
Abstract
A thermal radiation probe was constructed and tested in pulverized- coal-fired furnaces. A rotatable sensing head on the side of a water-cooled probe permitted measurement of radiant flux within a 7.2 Deg. Cone from any desired direction to a point within a furnace. A responsive curve for a corner-fired furnace showed radiant flux of 130,000 btu per square foot per hour, when sensing wall reflection. Detailed drawings and fabrication procedures are given.
Publication Date
19700101
Document Type
IH; Report of Investigation;
Fiscal Year
1970
NTIS Accession No.
PB-194945
NTIS Price
A03
Identifying No.
RI 7427
NIOSH Division
PERC;
Source Name
NTIS: PB 194 945
Page last reviewed: March 11, 2019
Content source: National Institute for Occupational Safety and Health Education and Information Division