NIOSHTIC-2 Publications Search

Design Criteria and Correction Factors for Field Wear Testing.

Authors
Blickensderfer-RA
Source
Proc Int'l Conf Wear/Mater Houston Texas, 4/5-9/87 Am Soc Mech Eng New York, New York,2:8 pages
Link
NIOSHTIC No.
10005671
Abstract
This paper describes some general criteria for wear testing. Laboratory wear tests can be designed to meet the criteria, but test results generally do not accurately predict wear under field conditions. Field wear testing is needed to optimize the final selection of materials for the given application. The concept of wear gradient is introduced. Wear gradients and their variation with time are small and reproducible in laboratory tests but generally are significant and not reproducible under field conditions. Field tests are classified as sequential series, concurrent series, and concurrent group tests. The use of reference specimens for establishing time averaged wear gradients is discussed, and formulas for correcting the test specimen wear for nonuniform tribological conditions over the test area are presented. A field test for abrasive wear of a linear array of specimens in a concurrent group test is described. The corrected wear values of duplicate specimens agreed within 3.4 pct of the mean.
Publication Date
19870101
Document Type
OP;
Fiscal Year
1987
Identifying No.
OP 47-87
NIOSH Division
ALRC;
Source Name
Proc. Int'l Conf Wear/Mater, Hous, Texas, 4/5-9/87. Am. Soc. Mech. Eng., New York, New York, V. 2, '87, 877-884
State
NY; TX;
Page last reviewed: April 12, 2019
Content source: National Institute for Occupational Safety and Health Education and Information Division