Abstract
This report covers test procedures for evaluating several underground coal mine trailing cable splices. Laboratory results were compared with actual field observations and experience. The results were used to define quantitatively the generalized terms of the 1969 coal mine health and safety act. Failure points in splices were detailed and presented for use by a Mining Enforcement and Safety Administration training program and by manufacturers attempting to improve product quality.