A Continuous-recording Methanometer for Exhaust Fan Monitoring.

Authors
Irani-MC; Jeran-PW
Source
Proc 2nd WVU Conf on Coal Mine Electrotec 1974 Jun; :15.1-15.16
Link
NIOSHTIC No.
10000771
Abstract
A continuous-recording methanometer utilizing a catalytic combustion detector has been developed and is presently operating at 22 exhaust fans at 14 mines in the eastern coalfields. The instrument is reliable and simple to install, operate, and maintain. The instrument and the details of its installation and calibration are described. Analytical data obtained by infrared spectrophotometer and gas chromatograph are presented to substantiate its reliability.
Publication Date
19740601
Document Type
OP;
Fiscal Year
1974
Identifying No.
OP 65-75
NIOSH Division
PRC;
Source Name
Proc. 2nd WVU Conf. on Coal Mine Electrotec., June 12-14, 1974, Morgantown, West Virginia, PP. 15.1-15.16
State
WV;
Page last reviewed: May 5, 2020