The backup data report is given for validating the method for determining vanadium-pentoxide (1314621) fume in the air. Samples were analyzed regarding collection efficiency on mixed cellulose ester membrane filter, storage stability, and precision and accuracy of the method. The coefficient of variation is 0.067. Attachments include procedures for aerosol generation/dilution/sampling system and for fume generation, including diagrams, and a summary of statistical terms and formulae.