NIOSHTIC-2 Publications Search

NIOSH Analytical Method, Benzoyl Peroxide, S253, (Set 2).

Authors
NIOSH
Source
NIOSH 1977 Jul:7 pages
Link
NIOSHTIC No.
00076494
Abstract
The method is described for determining benzoyl-peroxide (94360) in the air, including the principle, range and sensitivity, interferences, precision and accuracy, advantages and disadvantages, apparatus, reagents, calibration and standards, and calculations. The principle is based upon high pressure liquid chromatography of a sample collected through a mixed cellulose ester membrane filter and extracted with ethyl-ether. The range is 3.12-19.10 milligrams per cubic meter with a precision of 0.060 (coefficient of variation). The OSHA standard is 5 milligrams per cubic meter.
Keywords
NIOSH-Author; NIOSH-Analytical-Method; Standards-Completion-Program; SCP; Analytical-Method; Standards; Sampling; Set-2; Air-quality-measurement; Air-sampling; Procedures; Exposure-limits; Peroxides;
CAS No.
94-36-0;
Publication Date
19770701
Fiscal Year
1977
Identifying No.
S253
NIOSH Division
DPSE;
Source Name
Division of Physical Sciences and Engineering, NIOSH, Cincinnati, Ohio, 7 pages, 2 references
State
OH;
Page last reviewed: April 12, 2019
Content source: National Institute for Occupational Safety and Health Education and Information Division