NIOSHTIC-2 Publications Search

NIOSH Analytical Method, Allyl Glycidyl Ether, S346, (Set 2).

Authors
NIOSH
Source
NIOSH 1977 Jul:9 pages
Link
NIOSHTIC No.
00076491
Abstract
The method is described for determining allyl-glycidyl-ether (106923) in the air, including the principle, range and sensitivity, interferences, precision and accuracy, advantages and disadvantages, apparatus, reagents, calibration and standards, and calculations. The principle is based upon gas chromatography after desorption by diethyl-ether of the sample collected in a Tenax-GC tube. The range is 19-87 milligrams per cubic meter with a precision of 0.057 (coefficient of variation). The OSHA standard is 10ppm or 45 milligrams per cubic meter (ceiling).
Keywords
NIOSH-Author; NIOSH-Analytical-Method; Standards; Standards-Completion-Program; SCP; Analytical-Method; Sampling; Set-2; Air-quality-measurement; Air-sampling; Procedures; Exposure-limits; Ethers;
CAS No.
106-92-3;
Publication Date
19770701
Fiscal Year
1977
Identifying No.
S346
NIOSH Division
DPSE;
Source Name
Division of Physical Sciences and Engineering, NIOSH, Cincinnati, Ohio, 9 pages, 3 references
State
OH;
Page last reviewed: April 12, 2019
Content source: National Institute for Occupational Safety and Health Education and Information Division