Teen Roofer Electrocuted when Ladder Contacts High Voltage Power Line
Kentucky Case Report: 18KY054
Release Date: January 16, 2019
The following report is the product of our Cooperative State partner and is presented here in its original unedited form from the state. The findings and conclusions in this report are those of the individual Cooperative State partner and do not necessarily reflect the views or policy of the National Institute for Occupational Safety and Health.
SUMMARY
At 12:15 pm on Monday, September 10, 2018, a 16-year-old male roofer (the victim) was killed when the metal ladder he was holding while on the ground contacted a high voltage line above him. On October 1, 2018, the Kentucky Fatality Assessment and Control Evaluation Program was notified of the incident via an online news source. On October 2, 2018, the Kentucky FACE investigator conducted a site visit. Photographs of the incident site and witness statements were taken at that time.
Teen Roofer Electrocuted when Ladder Contacts High Voltage Power Linepdf icon [PDF 775 KB]