CDC logoSafer Healthier People  CDC HomeCDC SearchCDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Draft Document for Public Review and Comment:

NIOSH Manual of Analytical Methods (NMAM) Method 7704, Beryllium by field-portable fluorescence (air) and NMAM Method 9110, Beryllium by field-portable fluorescence (wipes) NIOSH Docket #077

May 2006

Draft Document for Public Review and Comment

The National Institute for Occupational Safety and Health (NIOSH) invites comment on NIOSH 7704 (Beryllium in air) and NIOSH 9110 (Beryllium on wipes) NIOSH Docket #077

The information contained in this document is still in draft form and as such should not be considered as a final statement of NIOSH policy.

NIOSH 7704 and NIOSH 9110 have been submitted for publication in the NMAM, 5th Edition. Both proposed methods have an associated backup data report that contains additional information on the proposed method development and performance evaluation that is not included in the methods. The methods were developed by Los Alamos National Laboratory (LANL), and Berylliant, Inc. in cooperation with NIOSH and the Beryllium Health and Safety Committee, a group of government agencies and private sector companies. The methods have been independently evaluated by a NIOSH contract lab (DataChem Laboratories) and very similar methods were collaboratively tested by ASTM D-22 (Air Quality) Committee.

These methods were developed for use in the field to analyze for the presence of beryllium by sampling air or surfaces. This field-portable technique measures a dye which is specific for the beryllium atom and fluorescence at low concentrations.

NIOSH will consider all the comments submitted, and make appropriate revisions to these 2 methods. These methods will also undergo scientific peer review. The details of this public comment and the scientific review will be referenced on the NIOSH Web site in the near future.

Beryllium - DRAFT 7704 by Field-Portable Flourescence Measurement 7704 Air Method Dec 21 05.pdf
(147KB; 9 pgs)
Beryllium - DRAFT 9110 by Field-Portable Flourescence Measurement 9110 wipe method Dec 21 05.pdf
(143KB; 10 pgs)
BACKUP DATA - Method Nos. 7704 and 9110 / Beryllium - DRAFT Backup data report 12-21-05.pdf
(539KB; 83 pgs)
The free Adobe Acrobat Reader is needed to view these files. get acrobat reader


To submit comments regarding these draft publications, please use one of these options:

  • Send comments by email .  

  • Fax comments to the NIOSH Docket Office: 513-533-8285

  • Send by Mail to:
    NIOSH Mailstop: C-34
    Robert A. Taft Lab.
    4676 Columbia Parkway
    Cincinnati, Ohio 45226

NIOSH Home |  NIOSH Search  | Site Index  | Topic List | Contact Us