Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Laboratory faceseal leakage evaluation of N95 filtering facepiece respirators against nanoparticles and "all size" particles.

Authors
Zhuang-Z; Bergman-MS; Eimer-BC; Shaffer-RE
Source
J Occup Environ Hyg 2013 Sep; 10(9):496-504
NIOSHTIC No.
20042960
Abstract
National Institute for Occupational Safety and Health (NIOSH)-certified N95 filtering facepiece respirators (FFRs) are used for respiratory protection in some workplaces handling engineered nanomaterials. Previous NIOSH research has focused on filtration performance against nanoparticles. This paper is the first NIOSH study using human test subjects to compare N95 FFR faceseal leakage (FSL) performance against nanoparticles and "all size" particles. In this study, estimates of FSL were obtained from fit factor (FF) measurements from nine test subjects who participated in previous fit test studies. These data were analyzed to compare values obtained by: (1) using the PortaCount Plus (8020A, TSI, Inc., MN, USA) alone (measureable particle size range 20 nm to > 1,000 nm, hereby referred to as the "all size particles test"), and (2) using the PortaCount Plus with N95-CompanionTM accessory (8095, TSI, Inc., MN, USA) accessory (negatively charged particles, size range approximately 40 to 60 nm, hereby referred to as the "nanoparticles test"). Log-transformed FF values were compared for the "all size particles test " and "nanoparticles test" using one-way analysis of variance tests (significant at P < 0.05). For individual FFR models, geometric mean (GM) FF using the "nanoparticles test" was the same or higher than the GM FFs using "all size particles test." For all three FFR models combined, GM FF using the "nanoparticles test" was significantly higher than the GM FF using "all size particles test" (P < 0.05). These data suggests that FSL for negatively charged approximately 40-60 nm nanoparticles is not greater than the FSL for the larger distribution of charged and uncharged 20 to > 1,000 nm particles.
Keywords
Respirators; Respiratory-protection; Respiratory-protective-equipment; Face-masks; Nanotechnology; Particulate-dust; Particulates; Health-protection; Safety-equipment; Filters; Humans; Men; Women; Analytical-processes; Author Keywords: Nanoparticles; N95 filtering facepiece respirators; fit test; fit factors
Contact
Ziqing Zhuang, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, 626 Cochrans Mill Road, Building 13 PO Box 18070, Pittsburgh, PA 15236
CODEN
JOEHA2
Publication Date
20130901
Document Type
Journal Article
Email Address
zaz3@cdc.gov
Fiscal Year
2013
NTIS Accession No.
NTIS Price
Identifying No.
B20130805
Issue of Publication
9
ISSN
1545-9624
NIOSH Division
NPPTL
Priority Area
Manufacturing
Source Name
Journal of Occupational and Environmental Hygiene
State
PA
TOP