Evaluation of high-temperature disposable filter elements in an experimental underground mine.

Authors
Bugarski-AD; Schnakenberg-GH Jr.; Hummer-JA; Cauda-E; Janisko-SJ; Patts-LD
Source
SME Annual Meeting & Exhibit and CMA 113th National Western Mining Conference 2011, 28 February - 2 March 2011, Denver, Colorado, USA. Littleton, CO: Society for Mining, Metallurgy, and Exploration, Inc., 2011 Aug; :57-64
NIOSHTIC No.
20040392
Abstract
Filtration systems with disposable filter elements (DFEs) are used in the underground coal mining industry to control particulate matter emissions from diesel-powered permissible and nonpermissible coal mining equipment. This study was conducted in underground mine conditions to evaluate three types of high-temperature DFEs used in those filtration systems. The DFEs were evaluated for their effects on the concentrations and size distributions of diesel aerosols and concentrations of nitric oxide (NO) and nitrogen dioxide (NO2). Those effects were compared with the effects of a standard muffler. The experimental work was conducted directly in an underground environment using a unique diesel laboratory developed in an underground experimental mine. After an initial DFE degreening period, the filtration system with all three DFEs was found to be very effective at reducing total mass concentrations of aerosols in the mine air. The effectiveness of DFEs in filtering aerosol mass was found to be a function of the engine operating conditions. The efficiency of the new DFEs significantly increased with accumulation of operating time and buildup of diesel particulate matter in the porous structure of the filter elements. A single laundering process did not exhibit substantial effects on performance of the DFE elements. The effectiveness of DFEs in removing aerosols by number was strongly influenced by engine operating mode. The concentrations of nucleation mode aerosols in the mine air were found to be substantially higher for both DPFs and DFEs when the engine was operated at high-load modes than at low-load modes. Initial heating of certain DFEs resulted in visible white smoke and substantially elevated aerosol number concentrations. The effects of the DFEs on total nitrogen oxides (NOX) concentrations were found to be minor. The NO2 fraction was found to be generally lower for the DFEs than for the muffler. The engine-out NO2 fraction of the total NOX was found to be substantially higher for low-load modes than for high-load modes.
Keywords
Filtration; Emission-sources; Particulates; Mining-equipment; Mining-industry; Underground-mining; Aerosol-particles; Aerosols; Author Keywords: Diesel particulate matter; Underground mining; Disposable filter element
CAS No.
10102-43-9; 10102-44-0
Publication Date
20110801
Document Type
Conference/Symposia Proceedings
Fiscal Year
2011
NTIS Accession No.
NTIS Price
ISBN No.
9781617829727
NIOSH Division
OMSHR
Priority Area
Mining
Source Name
SME Annual Meeting & Exhibit and CMA 113th National Western Mining Conference 2011, 28 February - 2 March 2011, Denver, Colorado, USA
State
PA; CO