Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Effect of fit testing on the protection offered by N95 filtering facepiece respirators against fine particles in a laboratory setting.

Authors
Reponen-T; Lee-S-A; Grinshpun-SA; Johnson-E; McKay-R
Source
Ann Occup Hyg 2011 Apr; 55(3):264-271
NIOSHTIC No.
20040126
Abstract
OBJECTIVES: This study investigated particle-size-selective protection factors (PFs) of four models of N95 filtering facepiece respirators (FFRs) that passed and failed fit testing. Particle size ranges were representative of individual viruses and bacteria (aerodynamic diameter d(a) = 0.04-1.3 Ám). METHODS: Standard respirator fit testing was followed by particle-size-selective measurement of PFs while subjects wore N95 FFRs in a test chamber. PF values obtained for all subjects were then compared to those obtained for the subjects who passed the fit testing. RESULTS: Overall fit test passing rate for all four models of FFRs was 67%. Of these, 29% had PFs <10 (the Occupational Safety and Health Administration Assigned Protection Factor designated for this type of respirator). When only subjects that passed fit testing were included, PFs improved with 9% having values <10. On average, the PFs were 1.4 times (29.5/21.5) higher when only data for those who passed fit testing were included. The minimum PFs were consistently observed in the particle size range of 0.08-0.2 Ám. CONCLUSIONS: Overall PFs increased when subjects passed fit testing. The results support the value of fit testing but also show for the first time that PFs are dependent on particle size regardless of fit testing status.
Keywords
Humans; Men; Women; Laboratories; Laboratory-work; Respirators; Respiratory-equipment; Respiratory-protection; Respiratory-protective-equipment; Particulate-dust; Particulates; Bacteria; Exposure-levels; Exposure-limits; Protective-equipment; Personal-protection; Personal-protective-equipment; Author Keywords: bioaerosols; fine particles; fit test; nanoparticles; N95; protection factor; respiratory protection
Contact
Tiina Reponen, Department of Environmental Health, University of Cincinnati, PO Box 670056, Cincinnati, OH 45267-0056
CODEN
AOHYA3
Publication Date
20110401
Document Type
Journal Article
Email Address
Tiina.Reponen@uc.edu
Funding Type
Grant
Fiscal Year
2011
NTIS Accession No.
NTIS Price
Identifying No.
Grant-Number-R01-OH-004085; B01182012
Issue of Publication
3
ISSN
0003-4878
Source Name
Annals of Occupational Hygiene
State
MN; OH
Performing Organization
University of Cincinnati
TOP