Levels of microbial agents in floor dust during remediation of a water-damaged office building.

Authors
Cho-SJ; Park-J-H; Kreiss-K; Cox-Ganser-JM
Source
Indoor Air 2011 Oct; 21(5):417-426
NIOSHTIC No.
20038801
Abstract
We examined the effects of remediation on loads of culturable fungi in floor dust collected from a large water-damaged office building during 4 cross-sectional surveys (2002, 2004, 2005, and 2007, respectively). We created a binary remediation variable for each year for each sampled workstation using information on remediation associated with water damage obtained from building management and used generalized linear mixed-effects models. We found significantly lower levels of culturable total and hydrophilic fungi at remediated workstations than at nonremediated workstations in 2004 and 2005 after completion of major remediation. The remediation effect, however, disappeared in 2007. The fraction of hydrophilic to total fungal concentrations was lowest in 2004, increased in 2005 and was highest in 2007. Our results indicate that the 2003 remediation lowered dust indices of dampness temporarily, but remediation was incomplete, consistent with a building assessment report of water infiltration. This study demonstrates the utility of longitudinal evaluation of microbial indices during remediation of water damage in this building, in which elimination of sources of moisture was not fully addressed. Our findings indicate that the fraction of hydrophilic fungi derived from concentrations of fungal species may be a useful index for assessing the long-term effectiveness of remediation.
Keywords
Dust-analysis; Dust-collection; Dust-exposure; Exposure-assessment; Filtration; Indoor-air-pollution; Indoor-environmental-quality; Mathematical-models; Microorganisms; Microscopic-analysis; Models; Particulate-dust; Particulate-sampling-methods; Work-environment; Workplace-studies; Author Keywords: mold; hydrophilic fungi; endotoxin; water damage; remediation; office building
Contact
Ju-Hyeong Park, National Institute for Occupational Safety and Health, Division of Respiratory Disease Studies, MS 2800, 1095 Willowdale Road, Morgantown, WV 26505 USA
CODEN
INAIE5
Publication Date
20111001
Document Type
Journal Article
Fiscal Year
2012
NTIS Accession No.
NTIS Price
Issue of Publication
5
ISSN
0905-6947
NIOSH Division
DRDS
Priority Area
Services
Source Name
Indoor Air
State
WV
TOP