Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Improvments in conveyor belt fire suppression systems for US coal mines.

Authors
Teacoach-KA; Rowland-JH; Smith-AC
Source
Trans Soc Min Metal Explor TP-10-018, 2011 Jan; 328:502-506
NIOSHTIC No.
20038053
Abstract
Current regulations for fire suppression systems in underground coal mines to protect conveyor belt installations have been in place since the Coal Mine Health and Safety Act of 1969 was enacted. Over time, the coal conveyer equipment being used and ventilation conditions underground have changed significantly, particularly the width of the conveyor belts and the use of belt air at the face. The effect of these new conditions on the effectiveness of suppression systems during a fire is not known. The National Institute of Occupational Safety and Health (NIOSH) conducted a study to evaluate the effect of air velocity, water sprinkler activation temperature and a limited water application time on the effectiveness of water sprinkler fire suppression systems to extinguish large-scale conveyor belt fires. The fire tests were conducted using both new and used 1.8-m-wide, fire-resistant rubber belt that met the Mine Safety and Health Administration (MSHA) flame-resistant requirement specified in Title 30, Code of Federal Regulations, part 18, section 18.65 (also known as the 2G test). Tests were conducted using standard response sprinklers with activation temperatures of 68 degrees C and 141 degrees C at air velocities of 0.5 and 5.1 m/s. Two tests were conducted at both air velocities for each sprinkler activation temperature, one using a new belt and one with a used belt. The results showed that the suppression system was able to suppress the fires in ten minutes to the point that a miner could extinguish it with a fire hose. However, in several of the tests, the fire reestablished itself a few minutes after the sprinkler water supply was cut off and quickly grew out of control. This report discusses the large-scale experimental configuration, the installation specifications of the fire suppression system and the results and conclusions regarding the effect of air velocity, sprinkler activation temperature and limited water application on the suppression system performance.
Keywords
Coal-miners; Coal-mining; Coal-workers; Fire-fighting; Fire-hazards; Fire-resistant-materials; Fire-safety; Injury-prevention; Mine-disasters; Mine-fires; Miners; Mine-workers; Mining-equipment; Mining-industry; Safety-engineering; Safety-equipment; Safety-measures; Safety-monitoring; Safety-practices; Safety-research; Temperature-effects; Temperature-measurement; Underground-miners; Underground-mining; Ventilation; Ventilation-equipment; Ventilation-systems; Work-environment; Workplace-studies; Author Keywords: Underground mining; Conveyor belts; Fire suppression; Health and safety
CODEN
TMENAE
Publication Date
20110101
Document Type
Journal Article
Fiscal Year
2011
NTIS Accession No.
NTIS Price
ISSN
1075-8623
NIOSH Division
OMSHR
Priority Area
Mining
Source Name
Transactions of the Society for Mining, Metallurgy, and Exploration
State
PA