Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Development of a new dynamometer for measuring grip strength applied on a cylindrical handle.

Authors
Wimer-B; Dong-RG; Welcome-DE; Warren-C; McDowell-TW
Source
Med Eng Phys 2009 Jul; 31(6):695-704
NIOSHTIC No.
20035574
Abstract
The objective of this study is to enhance the understanding of the hand grip force applied to a cylindrical handle and to develop a new dynamometer for measuring maximum grip force or grip strength. Specifically, a 40mm instrumented cylindrical handle with six measuring arms was developed. A theoretical model was proposed and used to analyze the principle of the measurement. Human test subjects were used in conducting two sets of experiments to evaluate the handle and to assess the measurement method. This study confirmed that some friction force exists in the grip-only action, but its level is not comparable with the normal force. This study also found that the friction force can stabilize the grip action and marginally increase the grip strength. No reliable correlation between the grip strengths measured with the 40mm cylindrical handle and Jamar handle with a 47.6mm span was observed. This suggests that grip strength measured with Jamar handle may not be reliably applicable to the design and risk assessment of some tools or machines with cylindrical handles. In contrast, the cylindrical handle proved to be able to determine the overall grip strength for a subject, as well as show the grip force distribution around the circumference of the handle. The handle is accurate with less than 4% error, and it demonstrates that the measurement is independent of the loading position along the handle. Therefore, this study concluded that this new dynamometer is suitable for measuring grip strength with sufficient precision.
Keywords
Biodynamics; Biomechanical-engineering; Biomechanics; Biomedical-engineering; Engineering; Hand-injuries; Hand-tools; Measurement-equipment; Muscle-physiology; Muscle-stress; Musculoskeletal-system; Musculoskeletal-system-disorders; Nerve-function; Neurological-system; Statistical-analysis; Toolmaking; Author Keywords: Grip force; Grip strength; Hand force; Instrumented handle; Dynamometer
Contact
Ren G. Dong, Engineering & Control Technology Branch, National Institute for Occupational Safety and Health, 1095 Willowdale Road, Morgantown, MS L-2027, WV 26505
CODEN
MEPHEO
Publication Date
20090601
Document Type
Journal Article
Email Address
rkd6@cdc.gov
Fiscal Year
2009
NTIS Accession No.
NTIS Price
Issue of Publication
6
ISSN
1350-4533
NIOSH Division
HELD
Source Name
Medical Engineering & Physics
State
WV