Computational fluid dynamics modeling of ventilation of confined-space manure storage facilities: applications.

Authors
Zhao-J; Manbeck-HB; Murphy-DJ
Source
J Agric Saf Health 2008 Nov; 14(4):405-429
NIOSHTIC No.
20034745
Abstract
Fatalities associated with entry into on-farm confined-space manure storage tanks occur each year The fatalities are due to asphyxiation or poisoning by exposure to high concentrations of hydrogen sulfide, methane, and carbon dioxide. Forced ventilation has been shown to be an effective way to reduce concentrations of these noxious gases to levels that are safe for human entry into these storage tanks. Hydrogen sulfide (H2S) was used as an indicator gas to investigate the effectiveness of forced ventilation strategies for eliminating the toxic and oxygen-deficient atmospheres in confined-space manure tanks. Validated computational fluid dynamics (CFD) modeling protocols were used to simulate H2S evacuation from fan-ventilated manure tanks. The simulation studies were conducted for rectangular and circular manure tanks, and the effects of pollutant source, inter-contamination (process by which a portion of exhausted contaminant gas enters a ventilated confined airspace through the fresh air intake), storage size (i.e., length, diameter), and air exchange rate on H2S removal from fan-ventilated manure tanks were investigated. For the same air exchange rate, as the size (i.e., length, diameter) of the tank increased, the rate of evacuation of the H2S from the confined space decreased. For rectangular and circular manure tanks, the higher the air exchange rate, the higher the rate of evacuation of the H2S from the confined space. For the rectangular tank geometries and ventilation system layouts simulated, evacuation times decreased exponentially with air exchange rate. Evacuation times for the circular tanks simulated decreased linearly with air exchange rate.
Keywords
Agriculture; Agricultural-industry; Agricultural-workers; Occupational-hazards; Confined-spaces; Toxic-gases; Ventilation; Ventilation-equipment; Ventilation-systems; Air-contamination; Air-quality-monitoring; Air-treatment-equipment; Air-samples; Risk-analysis; Risk-factors; Storage-facilities; Gases; Exhaust-ventilation; Author Keywords: Air exchange rate; CFD modeling protocols; Confined-space manure storage facilities; Forced ventilation; Hydrogen sulfide; Simulation
Contact
Department of Agricultural and Biological Engineering, The Pennsylvania State University, University Park, PA 16802
CODEN
JASHFD
CAS No.
7783-06-4; 74-82-8; 124-38-9
Publication Date
20081101
Document Type
Journal Article
Funding Type
Cooperative Agreement
Fiscal Year
2009
NTIS Accession No.
NTIS Price
Identifying No.
Cooperative-Agreement-Number-U50-OH-007542
Issue of Publication
4
ISSN
1074-7583
Priority Area
Agriculture, Forestry and Fishing
Source Name
Journal of Agricultural Safety and Health
State
PA; NY
Performing Organization
Mary Imogene Bassett Hospital - Cooperstown, New York
TOP