Exposure assessment by physiologic sampling pump - prediction of minute ventilation using a portable respiratory inductive plethysmograph system.

Authors
Lin-M-I; Groves-WA; Freivalds-A; Lee-EG; Harper-M; Slaven-JE; Lee-L
Source
J Environ Monit 2008 Sep; 10(9):1179-1186
NIOSHTIC No.
20034602
Abstract
A study was conducted to evaluate a portable respiratory inductive plethysmograph (RIP) as a means to estimate minute ventilation (E) for use in controlling the flow rate of a physiologic sampling pump (PSP). Specific aims were to: (1) evaluate the ability of the portable RIP system to measure E using a direct (individual) fixed-volume calibration method (Direct RIP model), (2) develop and evaluate the performance of indirect (group) regression models for E prediction using output data from the portable RIP and subject demographic characteristics (Indirect RIP model), and (3) compare E estimates from indirect and direct portable RIP calibration with indirect estimation models published previously. Nine subjects (19-44 years) were divided into calibration (n = 6) and test (n = 3) datasets and performed step-tests on three different days while wearing the portable RIP and breathing through a pneumotachometer (reference). Minute ventilation and portable RIP output including heart rate, breathing rate, and a motion index were recorded simultaneously during the 80 minute sessions. Calibration data were used to develop a regression model for E prediction that was subsequently applied to the test dataset. Direct calibration of the portable RIP system produced highly variable estimates of E (R2 = 0.62, average % error = 15 50) while Indirect RIP model results were highly correlated with the reference (R2 = 0.80-0.88) and estimates of total volume were within 10% of reference values on average. Although developed from a limited dataset, the Indirect RIP model provided an alternative approach to estimation of E and total volume with accuracy comparable to previously published models.
Keywords
Analytical-methods; Analytical-processes; Analytical-chemistry; Statistical-analysis; Risk-analysis; Risk-factors; Mathematical-models; Respiratory-equipment; Respiratory-protection; Respiratory-protective-equipment; Workplace-studies; Work-environment; Pulmonary-system
Contact
William A. Groves, The Pennsylvania State University, University Park, PA 16802-5000
CODEN
JEMOFW
Publication Date
20080901
Document Type
Journal Article
Fiscal Year
2008
NTIS Accession No.
NTIS Price
Issue of Publication
9
ISSN
1464-0325
NIOSH Division
HELD
Priority Area
Construction; Manufacturing
Source Name
Journal of Environmental Monitoring
State
WV; PA
TOP