Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

What does respirator certification tell us about filtration of ultrafine particles?

Authors
Eninger-RM; Honda-T; Reponen-T; McKay-R; Grinshpun-SA
Source
J Occup Environ Hyg 2008 May; 5(5):286-295
NIOSHTIC No.
20033411
Abstract
Recent interest in exposures to ultrafine particles (less than 100 nm) in both environmental and occupational settings led the authors to question whether the protocols used to certify respirator filters provide adequate attention to ultrafine aerosols. The authors reviewed the particle size distribution of challenge aerosols and evaluated the aerosol measurement method currently employed in the National Institute for Occupational Safety and Health (NIOSH) particulate respirator certification protocol for its ability to measure the contribution of ultrafine particles to filter penetration. Also considered were the differences between mechanical and electrically charged (electret) filters in light of the most penetrating particle size. It was found that the sodium chloride (NaCl) and dioctylphthalate (DOP) aerosols currently used in respirator certification tests contain a significant fraction of particles in the ultrafine region. However, the photometric method deployed in the certification test is not capable of adequately measuring light scatter of particles below approximately 100 nm in diameter. Specifically, 68% (by count) and 8% (by mass) of the challenge NaCl aerosol particles and 10% (by count) and 0.3% (by mass) of the DOP particles below 100 nm do not significantly contribute to the filter penetration measurement. In addition, the most penetrating particle size for electret filters likely occurs at 100 nm or less under test conditions similar to those used in filter certification. The authors conclude, therefore, that the existing NIOSH certification protocol may not represent a worst-case assessment for electret filters because it has limited ability to determine the contribution of ultrafine aerosols, which include the most penetrating particle size for electret filters. Possible strategies to assess ultrafine particle penetration in the certification protocol are discussed.
Keywords
Microbial-test-systems; Microbiology; Airborne-particles; Inhalation-studies; Air-contamination; Air-quality; Air-samples; Air-sampling-equipment; Air-sampling; Particulate-dust; Particulate-sampling-methods; Particle-aerodynamics; Sampling-methods; Sampling; Exposure-assessment; Exposure-methods; Statistical-analysis; Aerosols; Nanotechnology
Contact
Sergey A. Grinshpun, University of Cincinnati, Department of Environmental Health, 3223 Eden Ave., POB 670056, Cincinnati, OH 45267-0056
CODEN
JOEHA2
Publication Date
20080501
Document Type
Journal Article
Email Address
sergey.grinshpun@uc.edu
Funding Type
Grant
Fiscal Year
2008
NTIS Accession No.
NTIS Price
Identifying No.
Grant-Number-T42-OH-008432
Issue of Publication
5
ISSN
1545-9624
Source Name
Journal of Occupational and Environmental Hygiene
State
OH
Performing Organization
University of Cincinnati
TOP