Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Bioaerosol lung damage: Trout's response.

Environ Health Perspect 2001 Nov; 109(11):A516-A517
In his letter referring to our recent paper in EHP, Sudakin points out that hypersensitivity lung diseases have been shown to be associated with exposure to thermophilic actinomycetes such as Thermoactinornyces vulgaris. Exposures to these organisms related to lung disease have been reported in both outdoor settings (when handling materials such as compost or decomposing organic matter-the classic example being farmer's lung) and indoor settings. Regarding the indoor environment, reported exposures to thermophilic organisms that cause documented hypersensitivity lung disease have occurred in situations involving contamination of air-handling systems, primarily heating and/or humidification systems. Thermophilic fungi (thermophiles) grow optimally at temperatures between 35" and 50C (95"-122F) or hotter. In contrast, most fungi are considered mesophiles, growing optimally between 15" and 30C (59'-86F). concerning the source of the antigens to which the person was exposed. The primary problem in the building of concern in our report around the time of the patient's illness (and our evaluation) was large-scale water incursion allowing for massive fungal contamination of building materials in multiple areas of the building. These types of environmental conditions are not conditions in which thermophiles would be expected to grow well. As is commonly found in hotels, each room of the building in question had a dedicated unit ventilator to condition the occupied space. Inspection of selected unit ventilators in the building at the time of our evaluation revealed no obvious reservoirs of microbial growth. In addition, our evaluation, and the illness experienced by the patient in our report, took place during the cooling season when heating units would not routinely be in use. Given the above and the activities of the patient likely leading to aerosolization of the fungal contamination, there is no reason to believe exposure to thermophilic organisms played a role in this patient's building-related illness. It is unlikely that an environmental evaluation for thermophilic organisms in the areas that were grossly contaminated with fungi would have provided any useful information regarding the illness experienced by the patient discussed in our report. Additional discussion of the potential role of thermophilic organisms in the etiology of hypersensitivity lung diseases in general was beyond the scope of our paper.
Aerosols; Aerosol-particles; Lung-disease; Lung-disorders; Lung-irritants; Pulmonary-disorders; Pulmonary-system-disorders; Respiratory-irritants; Respiratory-system-disorders; Fungi; Air-contamination; Airborne-particles
Publication Date
Document Type
Email Address
Fiscal Year
NTIS Accession No.
NTIS Price
Issue of Publication
NIOSH Division
Source Name
Environmental Health Perspectives