Evaluating porous-layer open-tubular capillaries as vapor preconcentrators in a microanalytical system.

Authors
Zellers-ET; Morishita-M; Cai-QY
Source
Sens Actuators B Chem 2000 Sep; 67(3):244-253
NIOSHTIC No.
20030921
Abstract
Measuring environmental concentrations of organic vapors with microfabricated chemical sensors or sensor arrays often requires a means to enrich collected samples prior to detection. With such an application in mind, a preliminary evaluation is described of two porous-layer open tubular (PLOT) capillary traps as vapor preconcentrators for a series of vapors. Short (1-cm) sections of commercial PLOT-Q and PLOT-S capillary having wall coatings of styrene-divinylbenzene copolymer and vinylpyridine-divinylbenzene copolymer, respectively, are fitted with a metal sleeve for rapid thermal desorption of preconcentrated vapor samples, and tested using a downstream 97-MHz polyisobutylene-coated surface acoustic wave (SAW) sensor. Calibrated responses to vapors of 2-butanone (MEK), trichloroethylene (TCE), toluene, and m-xylene are collected with and without preconcentration. Dimethylmethylphosphonate could not be efficiently desorbed from either PLOT trap. For the remaining vapors, increases in sensitivity of 3-9-fold are achieved by preconcentrating and analyzing just 1 ml of sample air. Calculated limits of detection (LOD) range from 1-8 ppm. Differences in sensitivities are observed between the PLOT-Q and PLOT-S sampling trains for MEK and TCE. A theoretical model of penetration yields limiting values of flow rate and trap dimensions. Measured 10%-breakthrough times at 1 ml/min ranged from 1 to 6 min and, for PLOT-Q, are = modeled values obtained using the modified Wheeler equation. The implications of the results for the design and operation of microanalytical systems for vapor analytes are discussed.
Keywords
Vapors; Vapor-detectors; Organic-solvents; Solvents; Sampling; Sampling-methods
Contact
Department of Environmental Health Sciences, University of Michigan, 109 S. Observatory St., Ann Arbor, MI 48109-2029, USA
CODEN
SABCEB
Publication Date
20000901
Document Type
Journal Article
Email Address
ezellers@umich.edu
Funding Type
Grant
Fiscal Year
2000
NTIS Accession No.
NTIS Price
Identifying No.
Grant-Number-R01-OH-003692
Issue of Publication
3
ISSN
0925-4005
Source Name
Sensors and Actuators B: Chemical
State
MI
Performing Organization
University of Michigan, Ann Arbor
TOP