Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Floor sander dies when wood floor refinish product ignites.

Authors
Anonymous
Source
NIOSH 2006 Mar; :1-7
NIOSHTIC No.
20030062
Abstract
On July 2, 2005, a 43-year-old floor sander (the victim) was fatally injured when the one story single family house he was working in caught fire. The victim and a co-worker had just finished installing hardwood floors and were finishing them. The incident occurred when the flammable lacquer floor sealer that they were applying ignited, causing the house to catch fire. Calls were placed to Emergency Medical Services (EMS) and the fire department. Within minutes, EMS and fire department personnel arrived at the site to attend to the victim and control the fire. The victim was pronounced dead at the scene. The co-worker was able to exit the house without injuries. The Massachusetts FACE Program concluded that to prevent similar occurrences in the future, employers should: 1. Use wood floor finishing products that are less flammable (products with flash points greater than 100 F) for indoor applications. 2. Ensure that work areas are adequately ventilated during indoor application of wood floor finishing products. 3. Ensure that ignition sources including gas pilot lights are extinguished prior to beginning work. 4. Conduct job hazard analyses and implement and enforce a safety checklist to be completed prior to beginning work. 5. Develop, implement, and enforce a written hazard communication program that includes training employees about the chemicals they work with and the associated hazards and controls of these chemicals. The wood floor finishing industry and other stakeholders, such as contractors, insurance companies, and government agencies should: 6. Educate consumers about the hazards associated with finishing wood floors and actions that can be taken to minimize these hazards, such as the use of less flammable floor finishing products. Homeowners finishing wood floors themselves or through hired contractors should: 7. Ensure that only less flammable floor finishing products (products with flash points greater than 100 F) are used inside their homes. In addition, policymakers should: 8. Consider developing regulatory approaches to minimize the risk of fires and explosions during wood floor finishing.
Keywords
Region-1; Accident-analysis; Accident-prevention; Accidents; Injuries; Injury-prevention; Traumatic-injuries; Work-operations; Work-analysis; Work-areas; Work-performance; Work-practices; Safety-education; Safety-equipment; Safety-measures; Safety-monitoring; Protective-measures; Training; Flammable-liquids; Wood-products; Fire-hazards
Publication Date
20060324
Document Type
Field Studies; Fatality Assessment and Control Evaluation
Funding Type
Cooperative Agreement
Fiscal Year
2006
NTIS Accession No.
PB2006-109774
NTIS Price
A03
Identifying No.
FACE-05MA044; Cooperative-Agreement-Number-U60-CCU-108704
SIC Code
NAICS-23
Source Name
National Institute for Occupational Safety and Health
State
MA
Performing Organization
Massachusetts Department of Health
TOP