Investigation of fully grouted roof bolts installed under in situ conditions.

Compton-CS; Oyler-DC
Proceedings of the 24th International Conference on Ground Control in Mining, August 2-4, 2005, Morgantown, West Virginia. Peng SS, Mark C, Tadolini SC, Finfinger GL, Khair AW, Heasley KA, eds., Morgantown, WV: West Virginia University, 2005 Aug; :302-312
The NIOSH Pittsburgh Research Laboratory (PRL) continues to investigate the behavior of fully grouted roof bolts in the weak roof rock of PRL's Safety Research Coal Mine (SRCM). This paper describes the results of three studies: (1) a series of 24 pull tests of bolts installed fully grouted and overcored to leave 12 inches of grouted bolt. The tests compared the pullout performance of offset-head roof bolts with that of standard 5/8-inch bolts; (2) a second series of 24 tests that compared the pullout loads obtained by bolts installed with 1 ft of resin (a short- encapsulation pull test, or SEPT) to those of fully grouted bolts overcored to leave only 12 inches of grouted bolt; and (3) an investigation into the pressures generated during the installation of fully grouted resin bolts. All of the bolts installed and pulled were overcored and removed from the roof after the pull tests to allow inspection of the resin. The first study found that there was no significant difference in pullout load between the offset-head bolts and the standard bolts. The second study, which compared the SEPT bolts with the partially overcored fully grouted bolts, showed that SEPT can significantly underestimate bolt anchorage grip factor. This suggests that the SEPT is a conservative measure of actual bolt performance. Significant loss of resin to cracks in the roof was observed in the bolts overcored in the SRCM. The third study explored one possible explanation for the resin loss--high pressures generated during bolt installation. These tests used bolts installed in strain-gauged steel tubes. The results confirmed that significant pressures (greater than 4,000 psi) can be generated during bolt installation. The results of the pressure tests, combined with the observations of resin loss in bolts installed in the SRCM, suggest that under some circumstances resin loss and underencapsulation could take place and lead to degraded bolt performance. Glove fingering was observed in all recovered bolts to various degrees. The limited comparative data suggested that the effect of glove fingering ranged from slight to moderate. Complete mixing of the resin was observed on all of the 40 bolts recovered (28 fully grouted and 12 SEPT). Australian and U.S. resins were compared; the Australian resins were observed to have much smaller catalyst compartment areas and lower resin viscosities. These differences are suggested as potential explanations for occasional resin-mixing problems noted in Australian resin bolt installations.
Ground-control; Injuries; Coal-mining; Safety-research; Hazards; Mining-industry; Underground-mining; Geology
NIOSH Pittsburgh Research Laboratory, P.O. Box 18070, Pittsburgh, PA 15236
Publication Date
Document Type
Conference/Symposia Proceedings
Peng-SS; Mark-C; Tadolini-SC; Finfinger-GL; Khair-AW; Heasley-KA
Fiscal Year
NTIS Accession No.
NTIS Price
NIOSH Division
Priority Area
Research Tools and Approaches: Control Technology and Personal Protective Equipment
Source Name
Proceedings of the 24th International Conference on Ground Control in Mining, August 2-4, 2005, Morgantown, West Virginia