Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Re-evaluation of ventilation/filtration system for revised hand-cull stations of the 010 culling system at United States Postal Service Processing and Distribution Center, Baltimore, Maryland, report no. CT-279-22.

Authors
Hammond-D; Beamer-BR; Crouch-KG
Source
NIOSH 2005 Jun; :1-10
NIOSHTIC No.
20027353
Abstract
Researchers from the National Institute for Occupational Safety and Health (NIOSH) conducted an evaluation of a redesign of the Ventilation/Filtration System (VFS) developed for the United States Postal Service (UPS) mail processing equipment-the Hand-Cull stations of the 010 Culling System. The VFS was developed and installed by a private contractor hired by the USPS to reduce the potential for employee exposure to harmful substances that could be contained in mail pieces processed by the equipment. NIOSH was asked to assist the USPS in evaluating controls for this and other mail processing equipment after the 2001 terrorist attacks that used the mail as a delivery system for anthrax. Evaluations were based on air velocity measurements and smoke release observations. Both tests were made to evaluate contaminant capture efficiency of a redesign of the VFS at the Hand-Cull stations of the 010 Culling System. The redesign of the Hand-Cull stations was carried out not only to keep the curtain out of the workers' faces, but also to maximize the range of unimpeded motion. The following recommendation and conclusion were based on the results from this report. It is recommended that the USPS encourage its workers to work at the Hand-Cull stations with the curtains down in order to optimize the effectiveness of the local exhaust ventilation (LEV) to protect them from acts of bioterrorism. The performance of the VFS with the redesigned curtain is not appreciably different from the original configuration (114 fpm vs. 116 fpm).
Keywords
Engineering-controls; Control-technology; Ventilation; Ventilation-equipment; Ventilation-systems; Filtration; Postal-employees; Equipment-design; Biological-weapons; Air-flow; Air-quality-monitoring; Region-3
Contact
National Institute for Occupational Safety and Health, Division of Applied Research and Technology, Engineering and Physical Hazards Branch, Mail Stop R-5, 4676 Columbia Parkway, Cincinnati, OH 45226-1998
Publication Date
20050601
Document Type
Field Studies; Control Technology
Fiscal Year
2005
NTIS Accession No.
PB2006-100413
NTIS Price
A03
Identifying No.
CT-279-22
NIOSH Division
DART
SIC Code
4311
Source Name
National Institute for Occupational Safety and Health
State
MD; OH
TOP