Electrospray ionization tandem mass spectrometry (ESI-MS/MS) analysis of 1-Bromopropane mercapturic acid in human urine.

Cheever-KL; Marlow-KL; Stinson-D; Teass-AW; DeBord-DG
Proceedings of the International Conference on Occupational and Environmental Exposures of Skin to Chemicals: Science & Policy, Arlington, VA, September 8-11, 2002. Morgantown, WV: National Institute for Occupational Safety and Health, 2002 Sep; :1-2
1-Bromopropane (1-BP, CAS 106-95-5), used as an alternative solvent to chlorofluorocarbons and 1,1,1-trichloroethane, has been reported to cause reproductive and neurotoxicity in male rats. The related 2-bromopropane has been shown to cause similar toxicity in rats as well as amenorrhea, oligozoospermia, and anemia induction in workers. Although the mechanism of action of 1-BP has yet to be explained, it is thought that metabolic activation to reactive intermediates may be important. Metabolism of 1-BP is complex and is reported to occur by pathways which include debromination, oxidation by CYP2E1 and glutathione S-conjugation. 3-Bromopropionic acid and n-propanol are reported urinary metabolites of 1-BP whereas the glutathione conjugate, S-n-propyl-glutathione is further cleaved to S-n-propyl-L-cysteine and further to mercapturic acids N-acetyl-S-(n-propyl)-L-cysteine (M1), N-acetyl-S-(n-propyl)-L-cysteine-S-oxide (M2), N-acetyl-S-(2-carboxyethyl)-L-cysteine (M3), and N-acetyl-S-(3-hydroxy-n-propyl)-L-cysteine (M4). A potential biomonitoring method was developed to measure urinary levels of (M1), (M2), (M3) and (M4). The mercapturic acid standards as well as the stable isotope-labeled analog of (M1) internal standard were synthesized using the general procedure of van Bladern et al. (1980). A BenchMate« II robotic workstation was used to automate sample preparation. Bond Elute« 500 mg C18 SPE columns were conditioned with acetone, MeOH (5% HCl) and 5% MeOH in H2O pH 3. Samples were mixed with internal standard and loaded onto columns. A fraction containing >90% of 1-BP metabolites was collected in 3-mL acetone, reduced to dryness under N2 and dissolved in 1 mL MeOH for HPLC-MS/MS (ThermoQuest Finnegan LCQ tandem mass spectrometer) analysis on a 150 X 2 mm Phenomenex Aqua 3Ám C18 300A column. Chromatographic standards were chromatographed using a 10-min linear gradient H2O 1% acetic acid to MeOH 1% acetic acid at 300 microliters/min to elute the compounds of interest within 10 min. During the chromatographic run the mass spectrometer was operated in multiple segments using ESI-MS/MS, in the positive ion mode for detection of protonated (M1), (M2), (M3) and (M4) and Selected Reaction Monitoring of major transition products. Urine samples fortified with a mixture of standards were mixed with 10 micrograms/mL of internal standard and processed for evaluation of recovery, limits of detection (LOD) and limits of quantitation (LOQ). Calibration of (M1), (M2), (M3) and (M4) was linear from 30 - 10000 ng/mL (r(2)>0.99). The sample preparation and analysis appears to offer significant advantages over typical preconcentration and derivatization procedures that would be required for GC-MS analysis of these compounds. Thus, 1-BP internal exposure levels for various exposure situations can be rapidly determined by analysis of these metabolites in a single assay using a selective automated sample preparation system.
Chemical-properties; Chemical-processing; Urinalysis; Urine-chemistry; Biomarkers; Metabolites; Exposure-assessment; Chromatographic-analysis; Analytical-chemistry; Mass-spectrometry; Analytical-methods; Analytical-processes
Publication Date
Document Type
Fiscal Year
NTIS Accession No.
NTIS Price
NIOSH Division
Source Name
Proceedings of the International Conference on Occupational and Environmental Exposures of Skin to Chemicals: Science & Policy, Arlington, VA, September 8-11, 2002