Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Chinese immigrant restaurant owner electrocuted.

Authors
Anonymous
Source
NIOSH 2003 Aug; :1-6
NIOSHTIC No.
20026419
Abstract
On August 12, 2002, at 6:40 pm, a Chinese immigrant restaurant owner (decedent) died after being electrocuted by 110 volts of electricity. The restaurant owner and his wife were refurbishing a restaurant they had recently purchased. They spent the day cleaning the kitchen area while waiting for a washing machine repairman to arrive. Earlier in the day, the decedent had removed the electric cord to a single door, glass-fronted vertical cooler on rollers. He replaced the electrical cord from the unit with an electrical cord he had fabricated himself by attaching one end of a 10 foot length of 10/2 wire to the cooler and the other end to one-foot length of extension cord which plugged into the wall receptacle. The unit was moved around the kitchen all day while the kitchen was cleaned. The ground wire on the 10/2 length of wire came loose and came in contact with the metal frame of the cooler. The owner then moved the cooler eight to twelve inches cattycorner to a gas cook stove. The owner, who was hot, sweaty and shirtless bent down between the cook stove and the cooler. As he did so, his chest touched the outside aluminum casing of the cooler as his back touched the metal stove. He was electrocuted when the electric current traveled from the cooler through him to ground through the stove. To prevent similar incidents from occurring, Kentucky Fatality Assessment and Control Evaluation program recommends: 1. Perform a hazard evaluation at work site before any work is commenced. 2. Only persons properly trained in electrical procedures should perform electrical services.
Keywords
Accident-analysis; Accident-potential; Accident-prevention; Accidents; Injuries; Injury-prevention; Safety-education; Safety-equipment; Safety-practices; Traumatic-injuries; Region-4; Electric-properties; Electrical-conductivity; Electrical-hazards; Electrical-properties; Electrical-safety; Electrical-systems; Electricity; Electrocutions; Author Keywords: Electrocution; 10/2 wire; self-fabricated extension cord; Immigrant
Publication Date
20030814
Document Type
Field Studies; Fatality Assessment and Control Evaluation
Funding Type
Cooperative Agreement
Fiscal Year
2003
NTIS Accession No.
PB2012-114007
NTIS Price
A02
Identifying No.
FACE-02KY131; Cooperative-Agreement-Number-U60-CCU-409879
SIC Code
NAICS-72
Source Name
National Institute for Occupational Safety and Health
State
KY
Performing Organization
Kentucky Department of Health Services
TOP