Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Elastic Pressure Distortion of the Volumes of a 1,000-Atmosphere Burnett Compressibility Apparatus Over the Temperature Range O Deg. to 75 Deg. C.

Authors
Briggs-TC; Howard-AR
Source
NTIS: PB 190 974 :22 pages
Link
NIOSHTIC No.
10008993
Abstract
A removable-jacket distortion apparatus was constructed and used to measure distortion coefficients for two high-pressure vessels. The measured distortion coefficients were used to compute distortion coefficients for volumes v1 and (v1 + v2) of a 1,000-atmosphere burnett compressibility apparatus for the temperature range o deg. to 75 deg. C. Young's modulus for armco 17-4 ph stainless steel, heat treated to condition h1150-m, was computed from experimentally determined distortion coefficients. A 10- to 14-percent correction to the values obtained for young's modulus may be required because pressure vessel end effects were neglected. The distortion coefficients of the compressibility apparatus are believed to be accurate to about 1 percent.
Publication Date
19700101
Document Type
IH; Report of Investigation;
Fiscal Year
1970
NTIS Accession No.
PB-190974
NTIS Price
A03
Identifying No.
RI 7366
NIOSH Division
HEFO;
Source Name
NTIS: PB 190 974