Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Determination of Metallic Aluminum in Recycled Glass.

Authors
Green-TE
Source
NTIS: PB 206 360 :7 pages
Link
NIOSHTIC No.
10008827
Abstract
A gas volumetric method was developed for determining metallic aluminum at the 0.01- to 0.3-percent level in 100-gram samples of recycled glass. The method is based on the measurement of the change in gas volume produced by the reaction 2 al + 2naoh + s h2o - > 2 naalo2 + 3 h2 using a simple apparatus assembled from readily available glassware. Apart from sampling errors, the precision of the method is within +/-5 percent. A minor modification of the apparatus would extend the method to larger samples or samples of higher metallic aluminum content.
Publication Date
19710101
Document Type
IH; Report of Investigation;
Fiscal Year
1971
NTIS Accession No.
PB-206360
NTIS Price
A02
Identifying No.
RI 7592
NIOSH Division
CPRC;
Source Name
NTIS: PB 206 360