Field Evaluation of Zinc-based Solders for Copper and Copper Alloys.

Authors
Beal-RE; Hill-RC
Source
NTIS: PB 258 111 Available for Reference At Bureau Libraries :50 pages
Link
NIOSHTIC No.
10008095
Abstract
This report describes a field evaluation of the Bureau of Mines zinc- based soldering system for copper and copper alloys. The soldering system utilizes a sacrificial nickel plating to promote spontaneous wetting of copper and copper alloys. Radiator capsules soldered with zinc-based solder and exposed to a simulated radiator life cycle functioned to 1,000 hours without failure while those employing the 70pb-30sn solder alloy normally used by radiator manufacturers failed after 250 hours.