Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Development of Improved Detection Instruments for Toxic Gas Contaminants in Mining Atmospheres.

Authors
Kosek-JA; Laconti-AB
Source
NTIS: PB/82-256223 :54 pages
Link
NIOSHTIC No.
10002580
Abstract
The objective of this investigation was to develop improved sensor cells for use in direct-reading detectors and diffusion-exposure meters. A pumped CO sensor cell was developed that has a shorter response time, improved temperature cycle characteristics, and improved linearity and stability at high CO concentrations. Diffusion CO sensor cells showed good response-level stability and linearity up to 1,000 ppm. In addition, a new sensor cell catalyst was developed for NO2 sensor cells that has a much shorter response time and improved response stability characteristcs.
Publication Date
19820101
Document Type
CP; Final Contract Report;
Fiscal Year
1982
NTIS Accession No.
PB82-256223
NTIS Price
A05
Identifying No.
OFR 137-82
NIOSH Division
PRC;
Source Name
NTIS: PB/82-256223
Performing Organization
General Electric Company
TOP