Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Airborne Radiation Warning System.

Authors
Franklin-JC; Shaw-DM
Source
Chap 148 in "Radiation Hazards in Mining: Control Measurement and Med Aspects" PP 980-983 :980-983
Link
NIOSHTIC No.
10002419
Abstract
A 32-channel warning system for high working level, fan operation, and airlock-doors has been constructed. The working level monitors have a microcomputer for accumulating the pulses, converting to working level, and triggering an alarm at a variable set point and at one working level. The system can detect changes in air velocity which indicate surface fan failures or changes in the ventilation system. Using this alarm system, the ventilation engineer will be alerted prior to excessive levels of radon daughters being reached so corrective action can be taken.
Publication Date
19810101
Document Type
OP;
Fiscal Year
1981
NTIS Accession No.
NTIS Price
Identifying No.
OP 44-82
NIOSH Division
DRC;
Source Name
Chap. 148 in "Radiation Hazards in Mining: Control, Measurement, and Med. Aspects", PP. 980-983