Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Mine Electrical Systems Evaluation - 5 Volume Set. Volume 1 - Cable Splicing.

Authors
Stefanko-R; Morley-LA; King-RH
Source
NTIS: PB/245-927 Available for Reference At Bureau Libraries :208 pages
Link
NIOSHTIC No.
10001221
Abstract
This report covers test procedures for evaluating several underground coal mine trailing cable splices. Laboratory results were compared with actual field observations and experience. The results were used to define quantitatively the generalized terms of the 1969 coal mine health and safety act. Failure points in splices were detailed and presented for use by a Mining Enforcement and Safety Administration training program and by manufacturers attempting to improve product quality.
Publication Date
19740101
Document Type
CP; Final Contract Report;
Fiscal Year
1974
NTIS Accession No.
PB-245927
NTIS Price
A11
Identifying No.
OFR 76(1)-75
NIOSH Division
PRC;
Source Name
NTIS: PB/245-927 Available for Reference At Bureau Libraries
State
PA;
Performing Organization
Pennsylvania State Univ.
TOP