Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Research and Development Contract for Detection of Electrical Faults in Mine Haulage Systems - Phase II.

Authors
Perron-RR; Martin-PG; Strong-PF
Source
NTIS: PB/259-205 :100 pages
Link
NIOSHTIC No.
10001208
Abstract
The results of an experimental program to evaluate subsystems of dicur, a differential current measurement system for the detection of low current faults on mine haulage system, are described. Tests were conducted to determine transmitter power for the telemetering locomotive load current data and the performance of a high current shunt. A dicur system was simulated and tested in the laboratory using a model locomotive having current magnitudes scaled down by a factor of 1,500 to 1. The report also discusses application and design of isolation diodes for mine haulage systems and presents an analyses of a random multiplexing telemetering system for the transmission of load current magnitudes.
Publication Date
19750101
Document Type
CP; Final Contract Report;
Fiscal Year
1975
NTIS Accession No.
PB-259205
NTIS Price
A06
Identifying No.
OFR 104-76
NIOSH Division
PRC;
Source Name
NTIS: PB/259-205
Performing Organization
A. D. Little, Inc.