Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Walk-through survey report: control technology for adhesives use at Drew Shoe Plant, Lancaster, Ohio, report no. CT-108-22a.

Authors
Mortimer-VD Jr.
Source
NIOSH 1983 Jul; :1-5
Link
NIOSHTIC No.
00183550
Abstract
A walk through survey was conducted at the Drew Shoe Facility, (SIC- 3144), Lancaster, Ohio to evaluate control measures for adhesives used in manufacturing women's leather shoes and sandals. The company employed about 300 people, with 90 percent of them in the production line. Basic operations included die cutting the individual parts, assembling the upper, attaching the bottom and heel, applying a finish and packing the shoes in boxes. Adhesives were used for permanently bonding some parts and for temporarily joining other parts to be stitched together later. A solvent based rubber cement was used for permanent bonding; a latex adhesive for temporary bonding. In warmer weather general ventilation was used heavily for comfort and vapor concentration control. Three large wall fans were installed and a small fan has been installed in another area of the facility. All floors were connected by an open stairway. Two adhesives application processes were performed under canopy hoods. Many operations not involving adhesive applications used local exhaust ventilation. Various coatings and finishes were applied in small spray booths. The author concludes that a control technology study of the use of adhesives in making shoes may promote cost effective methods to reduce solvent vapor concentrations. Such a study would examine alternatives to currently used adhesives in addition to ventilation, automation, and work practices.
Keywords
NIOSH-Author; NIOSH-Survey; Field-Study; Region-5; CT-108-22a; Adhesive-bonding; Leather-industry; Solvent-vapors; Ventilation-systems; Shoe-manufacturing; Spraying-booths
Publication Date
19830707
Document Type
Field Studies; Control Technology
Fiscal Year
1983
NTIS Accession No.
PB89-137855
NTIS Price
A01
Identifying No.
CT-108-22a
SIC Code
3144
Source Name
Engineering Control Technology Branch, NiOSH, Cincinnati, Ohio, Report No. CT-108-22a, 5 pages
State
OH