Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Use of tracer gas technique for industrial exhaust hood efficiency evaluation - where to sample?

Authors
Hampl-V; Niemela-R; Shulman-S; Bartley-DL
Source
Am Ind Hyg Assoc J 1986 May; 47(5):281-287
NIOSHTIC No.
00166471
Abstract
A tracer gas method employing sulfur-hexafluoride (SF6) was developed to estimate the efficiency of industrial exhaust hoods controlling gaseous and vaporous emissions, and a study was performed to determine the minimum sampling distance from the exhaust hood at which the sampling probe should be located to minimize error caused by the nonhomogeneous dispersion of SF6 in the duct. SF6 was measured with a gas chromatograph equipped with an electron capture detector. It was found that the sampling probe should be located in the straight duct at a minimum distance of approximately 50 duct diameters, where SF6 was considered to be dispersed uniformly across the duct cross section, and sampling could be conducted at any depth in the duct. With a straight duct side branch combination, the SF6 dispersion was somewhat accelerated and the minimum sampling distance was reduced to 25 and 40 duct diameters at Reynolds numbers of 120,000 and 200,000, respectively. For a straight duct with one elbow, the minimum distance was significantly reduced to 7 duct diameters. When two elbows were present, a minimum distance of approximately 4 duct diameters was found.
Keywords
NIOSH-Author; Industrial-hygiene; Toxic-vapors; Pollutants; Air-sampling-techniques; Analytical-methods; Quantitative-analysis; Air-monitoring; Exhaust-hoods
CODEN
AIHAAP
Publication Date
19860501
Document Type
Journal Article
Fiscal Year
1986
NTIS Accession No.
NTIS Price
Issue of Publication
5
ISSN
0002-8894
Source Name
American Industrial Hygiene Association Journal
TOP