Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Nu Tex Brick Plant, El Paso, Texas.

Authors
Craft-BF; Kunzen-RB
Source
NIOSH :5 pages
Link
NIOSHTIC No.
00111632
Abstract
Exposures to noise and silica (7631869) were measured at a third floor screening station at the Nu Tex Brick Factory (SIC-3255) in El Paso, Texas, on May 20, 1965. Overall sound pressure level was 105 decibels (dB). Levels at various octave bands ranged from 87dB to 105dB. Midget impinger samples at the station, settled dust samples, and one high volume air sample averaged 30 percent free silica. Impinger samples contained fewer than 7 million particles per cubic foot, the allowable dust concentration. The authors conclude there is no serious dust problem at this station.
Keywords
NIOSH-Author; NIOSH-Survey; Field-Study; Region-6; Health-surveys; Workplace-studies; Air-contamination; Health-services; Control-methods; Occupational-health-programs; Noise-analysis; Silicates; Dust-exposure; IWS-30-26;
CAS No.
7631-86-9;
Fiscal Year
1965
NTIS Accession No.
PB82-151242
NTIS Price
A01
Identifying No.
IWS-30-26
NIOSH Division
DFSCI;
SIC Code
3255;
Source Name
NIOSH, 5 pages
State
TX;