Sulfuryl Fluoride Analytical Method.

Authors
Anonymous
Source
NIOSH 1979 Jun:18 pages
Link
NIOSHTIC No.
00107285
Abstract
The NIOSH analytical method S245 for determining sulfuryl-fluoride (2699798) in air is described. Samples are collected in a gas sampling bag and are analyzed by gas chromatography with a flame photometric detector. The working range of the method is 2.54 to 10.29 parts per million, the coefficient of variance is 0.025, and the detection limit is 0.1 part per million. Analytical apparatus, reagents and procedures are described, and calculations are provided for determining sample concentrations. Data on recovery and stability rates is included.