Failure Report No. S252.

Authors
Anonymous
Source
NIOSH 1979 May:7 pages
Link
NIOSHTIC No.
00107284
Abstract
Test results using the NIOSH analytical method S252 for methyl- isocyanate (624839) are reported. Samples were collected on XAD-2 resin coated with 1-naphthylene-methylamine and were analyzed by high pressure liquid chromatography (HPLC) with a fluorescence detector, or were collected on resin coated with N-4-nitrobenzyl-N-n- propylamine (62869743) and analyzed by HPLC with an ultraviolet absorbance detector. Fluorescence reactions are described, and calibration data is included. Neither method was satisfactory due to slow reaction times and instability of the derivatizing agents.
Keywords
Insecticides; Sampling; Resins; Analytical-instruments; Coatings; Illumination; Radiation;
CAS No.
624-83-9; 62869-74-3;
Publication Date
19790511