Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Pyrethrum Analytical Method.

Authors
Anonymous
Source
NIOSH 1979 Aug:34 pages
Link
NIOSHTIC No.
00107275
Abstract
The NIOSH analytical method S298 for determining pyrethrum (8003347) in air is described. Samples are collected on a glass filter, extracted with acetonitrile and analyzed by high performance liquid chromatography with an ultraviolet detector at 225 nanometers. The working range of the method is 1.413 to 8.47 milligrams per cubic meter, the coefficient of variance is 0.702, and the detection limit is about 1.0 microgram per milliliter for a 25 microliter injection. Analytical apparatus, reagents and procedures are described, and calculations are provided for determining sample concentrations. Data on particle size distribution, collection efficiency, and recovery and stability rates is included.
Keywords
NIOSH-Analytical-Method; NIOSH-Sampling-Data-Sheet; NIOSH-Backup-Data-Sheet; Pesticides; Air-contamination; Air-sampling; Analytical-Method; Standards-Completion-Program; Standards; Sampling; SCP; Gas-filters; Ultraviolet-radiation; Analytical-instruments;
CAS No.
8003-34-7;
Publication Date
19790803
Fiscal Year
1979
NTIS Accession No.
PB81-244659
NTIS Price
A04
Identifying No.
S298
NIOSH Division
DPSE;
Source Name
NIOSH, Unpublished, Cincinnati, Ohio, 34 pages, 7 references