Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

Failure Report No. S21.

Authors
Anonymous
Source
NIOSH 1977 Oct:11 pages
Link
NIOSHTIC No.
00107080
Abstract
Test results using the NIOSH analytical method S21 for acrolein (107028) are reported. The procedure involves sample collection in a buffered Girard-T solution or in a midget bubbler charged with hydroxylamine solution, and analysis by differential pulse polarography. Analytical equipment and procedures are described along with generation of test atmospheres. Data on stability and recovery rate is included. The procedure using Girard-T reagent was unsatisfactory due to instability of the sample, and the collection efficiency of hydroxylamine was inadequate.
Keywords
NIOSH-Sampling-Data-Sheet; NIOSH-Backup-Data-Sheet; Chemical-analysis; Toxicology; Analytical-methods; Standards; Quantitative-analysis;
CAS No.
107-02-8;
Publication Date
19771028
Fiscal Year
1978
NTIS Accession No.
PB82-100660
NTIS Price
A03
Source Name
Unpublished, NIOSH, Cincinnati, Ohio, 11 pages, 8 references