Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

HHE determination report no. HHE-78-128-549, Nixon Power Plant, Colorado Springs, Colorado, December, 1978.

Authors
Gunter-BJ
Source
Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Public Health Service, Centers for Disease Control, National Institute for Occupational Safety and Health, HHE 78-128-549, 1978 Dec; :1-5
NIOSHTIC No.
00101030
Abstract
Asbestos (1332214) concentrations during sanding and buffing operations were measured at the Nixon Power facility (SIC-4911) in Colorado Springs, Colorado on September 29, 1978. The evaluation was requested by the vice president of the Watkin Construction Company on behalf of plumbers engaged in sanding asbestos joints and connections. Breathing zone asbestos concentrations of fibers greater than five microns in length ranged from 0.02 to 0.187 fibers per cubic centimeter. The OSHA asbestos standard of 2 fibers per cubic centimeter was not exceeded, however the author concludes that a potential asbestos hazard does exist. He recommends that respirators be used by workers until exhaust ventilation is provided.
Keywords
NIOSH-Author; HHE-78-128-549; NIOSH-Health-Hazard-Evaluation; Power-generation; Hazard-Unconfirmed; Region-8; Asbestos-products; Airborne-dusts; Air-contamination; Plumbers; Construction-workers; Work-practices; Air-sampling; Standards; Control-methods; Occupational-health-programs; Author Keywords: asbestos
CAS No.
1332-21-4
Publication Date
19781201
Document Type
Field Studies; Health Hazard Evaluation
Fiscal Year
1979
NTIS Accession No.
PB81-143117
NTIS Price
A01
Identifying No.
HHE-78-128-549
NIOSH Division
DSHEFS
SIC Code
4911
Source Name
National Institute for Occupational Safety and Health
State
CO; OH