Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

NIOSH Backup Data Report Ethyl-Chloride S105 (Set 4).

Authors
NIOSH
Source
NIOSH 1977 Jan:17 pages
Link
NIOSHTIC No.
00080647
Abstract
A protocol for validation of a method for the collection and analysis of ethyl-chloride (75003) was tested. For validation, the absolute total air monitoring error (sampling and analysis) should be less than 25 percent in at least 95 percent of the samples analyzed at the level of the OSHA standard. Validation included analysis of 18 analytical samples spiked with the appropriate amount of ethyl-chloride; analysis of 18 samples collected from dynamically generated test atmospheres; determination of the breakthrough capacity of activated coconut charcoal (16291966) at high relative humidity; testing of the storage stability of collected samples; assessment of precision and accuracy of the method. The method passed all program requirements.
Keywords
NIOSH-Author; NIOSH-Analytical-Method; Standards-Completion-Program; SCP; Standards; Sampling; Set-4; Analytical-Method; Backup-data; Chlorinated-hydrocarbons; Gases; Instrumentation; Methodology; Air-contaminants;
CAS No.
75-00-3; 16291-96-6;
Publication Date
19770102
Fiscal Year
1977
NTIS Accession No.
NTIS Price
Identifying No.
S105
NIOSH Division
DPSE;
Source Name
Division of Physical Sciences and Engineering, NIOSH, Cincinnati, Ohio, 17 pages, 4 references
State
OH;