Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

NIOSHTIC-2 Publications Search

Search Results

NIOSH Analytical Method, Methyl Chloride, Sampling Data Sheet, S99, (Set 2).

Authors
NIOSH
Source
NIOSH 1977 Jul:3 pages
Link
NIOSHTIC No.
00076520
Abstract
The data sheet is given for the sampling of methyl-chloride (74873) in the air and includes a brief summary of the analytical method, sampling equipment, sample size, sampling procedure, special considerations, and shipping instructions. A sample size of 0.5 liter for peak concentration is recommended with a sample flow rate of 0.10 liter per minute for 5 minutes, and for a time weighted average concentration it is 1.5 liters at 0.025 liter per minute. Special considerations include recharging the battery to the sampling pump at least every eight hours and noting condensation of water in the collection tube.
Keywords
NIOSH-Author; NIOSH-Analytical-Method; Standards-Completion-Program; SCP; Analytical-Method; Standards; Sampling; Set-2; Air-quality-measurement; Air-sampling; Procedures; Chlorinated-hydrocarbons; Anesthetics; Chloromethanes; Explosives; Refrigerants;
CAS No.
74-87-3;
Publication Date
19770701
Fiscal Year
1977
NTIS Accession No.
NTIS Price
Identifying No.
S99
NIOSH Division
DPSE;
Source Name
Division of Physical Sciences and Engineering, NIOSH, Cincinnati, Ohio, 3 pages, 1 reference
State
OH;
TOP